239x Filetype PDF File size 1.02 MB Source: www.bca.gov.sg
10. COMMON DEFECTS AND REMEDIES
Designers, contractors and site supervisory staff should understand the common defects and their related
causes to prevent them. It is also essential to use some recommended details to better manage the defects
and implement necessary remedial actions. Figure 10.1 shows the common defects, possible causes and
their remedial actions.
Figure 10.1 Common Defects, Possible Causes and Recommendations
Common Defects / Possible Causes Recommendations
Bad Practices
10.1.1 Cut pieces • Insufficient planning of • Plasterboard must be cut
layout according to shop drawing
• Late delivery of material • Allow tolerable gap for
flexible sealant
10.1.2 Stud cutting for switch • Insufficient planning • Stud placement must be
casing installation according to shop drawing
• Last minute changes (inclusive of M&E services
• Insufficient training layout)
• Stud realigned to
avoid switch casing or
alternatively, additional stud
is required
52
COMMON DEFECTS AND REMEDIES
Common Defects / Possible Causes Recommendations
Bad Practices
10.1.3 Poor cutting of • No provision of right tools • Panel must be cut according
plasterboard to shop drawing
• Insufficient training • Over cut / slanting / Rough
cut is not allowed
10.1.4 Missing timber stiffener • Insufficient planning • Timber (1x2 or 2x2) as
• Insufficient training stiffener
• Alternatively, it has to be
double studs to form boxed
at door jamb
10.1.5 Gaps between different • Insufficient planning • All gaps are to be sealed
materials using Fire Rated Sealant or
• No gap allowed • Insufficient training relevant sealant
• Gap was filled by mortar • Lack of supervision
filling instead of flexible
sealant.
53
COMMON DEFECTS AND REMEDIES
Common Defects / Possible Causes Recommendations
Bad Practices
10.1.6 Gaps between • Insufficient training • Joints must be tightly butt
plasterboard tapered end board edge
• Joints not tightly butt • Poor workmanship joints
tapered end board edge
joints
10.1.7 Studs not fastened to • Lack of supervision • All Studs and Bracing must
bottom track be riveted/ screwed
• Insufficient training
• Poor workmanship
54
COMMON DEFECTS AND REMEDIES
Common Defects / Possible Causes Recommendations
Bad Practices
10.1.8 M&E Services not • Insufficient planning • All Electrical Services must
within drywall setting out be within drywall setting out
• Insufficient training
• Poor workmanship
10.1.9 Small cut pieces • Insufficient planning • Full piece & proper joint.
installed and torn board
• Insufficient training
• Poor workmanship and
supervision
10.1.10 Bottom track cut to • Insufficient planning • Services Holes was created
accommodate M&E services without cutting track
• Insufficient training
• Poor workmanship and
supervision
55
no reviews yet